Product Physical Specification
|
|
Model Number |
CCT-NC-20 |
CCT-NC-30 |
CCT-NC-40 |
CCT-NC-90 |
CCT-NC-110 |
|
Internal Capacity |
565 ltr.
|
850 ltr.
|
1130 ltr.
|
2548 ltr.
|
3115 ltr. |
|
20 cu.ft.
|
30 cu.ft.
|
40 cu.ft.
|
90 cu.ft.
|
110 cu.ft.
|
|
Test Space
|
.94 square meter
|
1.40 square meter
|
1.74 square meter
|
2.21 square meter
|
4.18 square meter
|
|
Testing Plane
|
10.1 square feet
|
15.1 square feet
|
18.7 square feet
|
23.7 square feet
|
45 square feet
|
|
Internal Dimension
|
1270 mm L (50) |
1905 mm L (75) |
1905 mm L (75) |
1930 mm L (76) |
2267 mm L (89.25) |
|
L x W x H |
737 mm W (29) |
737 mm W (29) |
914 mm W (36) |
1143 mm W (45) |
1860 mm W (73.25) |
|
|
635 mm H (25) |
635 mm H (25) |
635 mm H (25) |
1155 mm H (45.5) |
762 mm H (30) |
|
Total Chamber Volume
|
982.5 ltr. |
1,472.5 ltr. |
1,925.5 ltr. |
3,822 ltr. |
4,870.5 ltr. |
|
34.7 cu.ft. |
52.0 cu.ft. |
68.1 cu.ft. |
135 cu.ft. |
172 cu.ft. |
|
Floor Space
|
2590 mm L (102) |
3226 mm L (127) |
3226 mm L (127) |
3353 mm L (132) |
3658 mm L (144) |
|
Required
|
2057 mm W (81) |
2057 mm W (81) |
2286 mm W (90) |
2540 mm W (100) |
3912 mm W (154) |
|
External Dimmensions
|
|
|
|
|
|
|
Left to Right |
2413 mm (95) |
3048 mm (120) |
3048 mm (120) |
3353 mm (132) |
3480 mm (137) |
|
Front to Back with cover on and closed |
914 mm (36) |
914 mm (36) |
1092 mm (43) |
1676 mm (66) |
2286 mm (90) |
|
Tall - Floor to top of cover (closed) |
1448 mm (57) |
1448 mm (57) |
1448 mm (57) |
2235 mm (88) |
1829 mm (72) |
|
|
|
|
|
|
|
|
|
The inside dimensions, capacities, and space given
here are available testing space. They do not include space below the false
floor where the heaters are located or within the cover.
|
|
Temperature Ranges: Ambient to 71 oC (160 oF)
|
|
Humidity:
95-100% During High Humidity from
Ambient to 50 oC (122 oF)
|
|
< 30% during Dry off cycles
|
Controllable Humidity available as an option upon request from
30-95% +/- 5% as limited by a 22oC
dew point and lab conditions. NOT ALL
TEMPERATURE AND HUMIDITY COMBINATIONS
ARE ATTAINABLE! (Check with factory
for details)
|
|
Solution Consumption during fogging tests only:
|
|
CCT-NC-20 approx. 10 gallons per day for D.I. water and salt
solution if a fog only cycle is running and no cycling takes place.
CCT-NC-30, 40 & 90 approx. 15 gallons per day for D.I. water and salt
solution if a fog only cycle is running and no cycling takes place.
NOTE: D.I. water
consumption increases with cyclic
testing when cycling from fogging to
non-fogging tests.
Air Consumption:
Approximately 3.5 CFM, must be a constant 95 psi (6.55 Bar) supply
of clean dry air or the machine will not run.
D.I. Requirement:
ASTM D1193 Type 4 water ONLY, must be a
constant - 60 100 psi (4.5
6.9 Bar) supply of clean water or the
machine will not run.
Sample Capacity:
|
|
|
CCT-NC-20 |
CCT-NC-30 |
CCT-NC-40 |
CCT-NC-90 |
|
4 x 12 panels |
160 |
240 |
360 |
390 |
|
3 x 6 panels |
190 |
280 |
380 |
416 |
|
|
Venting:
4.5 Diameter (114mm)
Drain
Main drain is Ύ (19 mm) pipe drain that must be free flowing and open at all times.
There are multiple drain lines depending
on options.
|
|
Model Number |
208/1/60
|
208/3/60
|
240/1/60
|
240/3/60
|
460/3/60
|
|
CCT-NC20 |
35 amps |
30 amps |
30 amps |
26 amps |
16 amps |
|
NC-20 with Immersion |
N/A |
68 amps |
N/A |
61 amps |
31 amps |
|
CCT-NC30 |
44 amps |
40 amps |
38 amps |
34 amps |
20 amps |
|
NC-30 with Immersion |
N/A |
77 amps |
N/A |
69 amps |
36 amps |
|
CCT-NC40 |
44 amps |
40 amps |
38 amps |
34 amps |
20 amps |
|
NC-40 with Immersion |
N/A |
77 amps |
N/A |
69 amps |
36 amps |
|
CCT-NC90 |
53 amps |
53 amps |
47 amps |
47 amps |
25 amps |
|
NC-90 with Immersion |
N/A |
165 amps |
N/A |
155 amps |
75 amps |
|
|
These amperage ratings are the actual amperage draw for the cabinet.480 volt 3 phase available as an option at additional cost.
|